Yanis Wang

9 exploits Active since May 2019
CVE-2018-7845 NOMISEC HIGH WORKING POC
Modicon - Info Disclosure
A CWE-125: Out-of-bounds Read vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of unexpected data from the controller when reading specific memory blocks in the controller over Modbus.
1 stars
CVSS 7.5
CVE-2018-7849 NOMISEC HIGH WORKING POC
Modicon - DoS
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause a possible Denial of Service due to improper data integrity check when sending files the controller over Modbus.
1 stars
CVSS 7.5
CVE-2018-7844 NOMISEC HIGH WORKING POC
Modicon - Info Disclosure
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading memory blocks from the controller over Modbus.
CVSS 7.5
CVE-2018-7846 NOMISEC CRITICAL WORKING POC
Modicon - Trust Boundary Violation
A CWE-501: Trust Boundary Violation vulnerability on connection to the Controller exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause unauthorized access by conducting a brute force attack on Modbus protocol to the controller.
CVSS 9.8
CVE-2018-7848 NOMISEC HIGH WORKING POC
Modicon - Info Disclosure
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading files from the controller over Modbus
CVSS 7.5
CVE-2018-7852 NOMISEC HIGH WORKING POC
Modicon - DoS
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when an invalid private command parameter is sent to the controller over Modbus.
CVSS 7.5
CVE-2018-7842 NOMISEC CRITICAL WORKING POC
Modicon - Privilege Escalation
A CWE-290: Authentication Bypass by Spoofing vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause an elevation of privilege by conducting a brute force attack on Modbus parameters sent to the controller.
CVSS 9.8
CVE-2018-7854 NOMISEC HIGH WORKING POC
Modicon - DoS
A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a denial of Service when sending invalid debug parameters to the controller over Modbus.
CVSS 7.5
CVE-2018-7843 NOMISEC HIGH WORKING POC
Modicon - DoS
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading memory blocks with an invalid data size or with an invalid data offset in the controller over Modbus.
CVSS 7.5