pr0v3rbs

8 exploits Active since Jan 2019
CVE-2025-32463 NOMISEC CRITICAL WORKING POC
Sudo <1.9.17p1 - Privilege Escalation
Sudo before 1.9.17p1 allows local users to obtain root access because /etc/nsswitch.conf from a user-controlled directory is used with the --chroot option.
514 stars
CVSS 9.3
CVE-2018-19986 WRITEUP CRITICAL WRITEUP
D-link Dir-818lw Firmware - OS Command Injection
In the /HNAP1/SetRouterSettings message, the RemotePort parameter is vulnerable, and the vulnerability affects D-Link DIR-818LW Rev.A 2.05.B03 and DIR-822 B1 202KRb06 devices. In the SetRouterSettings.php source code, the RemotePort parameter is saved in the $path_inf_wan1."/web" internal configuration memory without any regex checking. And in the IPTWAN_build_command function of the iptwan.php source code, the data in $path_inf_wan1."/web" is used with the iptables command without any regex checking. A vulnerable /HNAP1/SetRouterSettings XML message could have shell metacharacters in the RemotePort element such as the `telnetd` string.
CVSS 9.8
CVE-2018-19988 WRITEUP CRITICAL WRITEUP
D-Link DIR-868L Rev.B 2.05B02 - Command Injection
In the /HNAP1/SetClientInfoDemo message, the AudioMute and AudioEnable parameters are vulnerable, and the vulnerabilities affect D-Link DIR-868L Rev.B 2.05B02 devices. In the SetClientInfoDemo.php source code, the AudioMute and AudioEnble parameters are saved in the ShellPath script file without any regex checking. After the script file is executed, the command injection occurs. It needs to bypass the wget command option with a single quote. A vulnerable /HNAP1/SetClientInfoDemo XML message could have single quotes and backquotes in the AudioMute or AudioEnable element, such as the '`telnetd`' string.
CVSS 9.8
CVE-2018-19989 WRITEUP CRITICAL WRITEUP
D-Link DIR-822 - Path Traversal
In the /HNAP1/SetQoSSettings message, the uplink parameter is vulnerable, and the vulnerability affects D-Link DIR-822 Rev.B 202KRb06 and DIR-822 Rev.C 3.10B06 devices. In the SetQoSSettings.php source code, the uplink parameter is saved in the /bwc/entry:1/bandwidth and /bwc/entry:2/bandwidth internal configuration memory without any regex checking. And in the bwc_tc_spq_start, bwc_tc_wfq_start, and bwc_tc_adb_start functions of the bwcsvcs.php source code, the data in /bwc/entry:1/bandwidth and /bwc/entry:2/bandwidth is used with the tc command without any regex checking. A vulnerable /HNAP1/SetQoSSettings XML message could have shell metacharacters in the uplink element such as the `telnetd` string.
CVSS 9.8
CVE-2018-19990 WRITEUP CRITICAL WRITEUP
D-Link DIR-822 B1 202KRb06 - Path Traversal
In the /HNAP1/SetWiFiVerifyAlpha message, the WPSPIN parameter is vulnerable, and the vulnerability affects D-Link DIR-822 B1 202KRb06 devices. In the SetWiFiVerifyAlpha.php source code, the WPSPIN parameter is saved in the $rphyinf1."/media/wps/enrollee/pin" and $rphyinf2."/media/wps/enrollee/pin" and $rphyinf3."/media/wps/enrollee/pin" internal configuration memory without any regex checking. And in the do_wps function of the wps.php source code, the data in $rphyinf3."/media/wps/enrollee/pin" is used with the wpatalk command without any regex checking. A vulnerable /HNAP1/SetWiFiVerifyAlpha XML message could have shell metacharacters in the WPSPIN element such as the `telnetd` string.
CVSS 9.8
CVE-2018-20114 WRITEUP CRITICAL WRITEUP
Dlink Dir-818lw Firmware - OS Command Injection
On D-Link DIR-818LW Rev.A 2.05.B03 and DIR-860L Rev.B 2.03.B03 devices, unauthenticated remote OS command execution can occur in the soap.cgi service of the cgibin binary via an "&&" substring in the service parameter. NOTE: this issue exists because of an incomplete fix for CVE-2018-6530.
CVSS 9.8
CVE-2019-20082 WRITEUP CRITICAL WRITEUP
Asus Rt-n53 Firmware - Buffer Overflow
ASUS RT-N53 3.0.0.4.376.3754 devices have a buffer overflow via a long lan_dns1_x or lan_dns2_x parameter to Advanced_LAN_Content.asp.
CVSS 9.8
CVE-2019-6258 WRITEUP CRITICAL WRITEUP
D-link Dir-822 Firmware < 2.02krb06 - Buffer Overflow
D-Link DIR-822 Rev.Bx devices with firmware v.202KRb06 and older allow a buffer overflow via long MacAddress data in a /HNAP1/SetClientInfo HNAP protocol message, which is mishandled in /usr/sbin/udhcpd during reading of the /var/servd/LAN-1-udhcpd.conf file.
CVSS 9.8