Products

Showing 25 vulnerabilities on this page

Signals CISA KEV Ransomware Nuclei
Omron vulnerability results
VulnerabilityTitle and contextCVSSEPSSPoCsSignalsSTIX action

Out-of-bounds read vulnerability exists in CX-Programmer included in CX-One CXONE-AL[][]D-V4 Ver. 9.81 or lower. Opening a specially crafted project file may lead to information disclosure and/or the product being crashed.

CWE-125May 1, 2024
CVSS7.8v3.1EPSS0.245%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Path traversal vulnerability exists in Machine Automation Controller NJ Series and Machine Automation Controller NX Series. An arbitrary file in the affected product may be accessed or arbitrary code may be executed by processing a specially crafted request sent from a remote attacker with an administrative privilege. As for the details of the affected product names/versions, see the information provided by the vendor under [References] section.

CWE-22Mar 12, 2024
CVSS7.2v3.1EPSS0.88%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Directory Traversal in Project File Format allows overwrite (Zip Slip)

Project files may contain malicious contents which the software will use to create files on the filesystem. This allows directory traversal and overwriting files with the privileges of the logged-in user.

CWE-22Jan 22, 2024
CVSS7.8v3.1EPSS0.326%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Omron FINS memory protection susceptible to bruteforce

The Omron FINS protocol has an authenticated feature to prevent access to memory regions. Authentication is susceptible to bruteforce attack, which may allow an adversary to gain access to protected memory. This access can allow overwrite of values including programmed logic.

CWE-307Jan 22, 2024
CVSS8.6v3.1EPSS0.703%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Omron CJ-series and CS-series unauthenticated filesystem access.

An attacker with network access to the affected PLC (CJ-series and CS-series PLCs, all versions) may use a network protocol to read and write files on the PLC internal memory and memory card.

CWE-306Jan 10, 2024
CVSS8.6v3.1EPSS0.536%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Executable files writable by low-privileged users in Omron Sysmac Studio

Sysmac Studio installs executables in a directory with poor permissions. This can allow a locally-authenticated attacker to overwrite files which will result in code execution with privileges of a different user.

CWE-276Jan 10, 2024
CVSS5.5v3.1EPSS0.249%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Denial-of-service (DoS) vulnerability due to improper validation of specified type of input issue exists in the built-in EtherNet/IP port of the CJ Series CJ2 CPU unit and the communication function of the CS/CJ Series EtherNet/IP unit. If an affected product receives a packet which is specially crafted by a remote unauthenticated attacker, the unit of the affected product may fall into a denial-of-service (DoS) condition. Affected products/versions are as follows: CJ2M CPU Unit CJ2M-CPU3[] Unit

CWE-1284Aug 3, 2023
CVSS7.5v3.1EPSS0.866%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Omron CJ1M unit v4.0 and prior has improper access controls on the memory region where the UM password is stored. If an adversary issues a PROGRAM AREA WRITE command to a specific memory region, they could overwrite the password. This may lead to disabling UM protections or setting a non-ASCII password (non-keyboard characters) and preventing an engineer from viewing or modifying the user program.

CWE-284Mar 16, 2023
CVSS9.1v3.1EPSS0.621%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

OMRON CX-Programmer Out-of-bounds Write

OMRON CX-Programmer 9.78 and prior is vulnerable to an Out-of-Bounds Write, which may allow an attacker to execute arbitrary code.

CWE-787Oct 6, 2022
CVSS7.8v3.1EPSS0.61%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

OMRON CX-Programmer Out-of-bounds Write

OMRON CX-Programmer 9.78 and prior is vulnerable to an Out-of-Bounds Write, which may allow an attacker to execute arbitrary code.

CWE-787Oct 6, 2022
CVSS7.8v3.1EPSS0.61%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

OMRON CX-Programmer Out-of-bounds Write

OMRON CX-Programmer 9.78 and prior is vulnerable to an Out-of-Bounds Write, which may allow an attacker to execute arbitrary code.

CWE-787Oct 6, 2022
CVSS7.8v3.1EPSS0.61%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Omron CX-Programmer

Opening a specially crafted file could cause the affected product to fail to release its memory reference potentially resulting in arbitrary code execution.

CWE-416Sep 12, 2022
CVSS7.8v3.1EPSS0.236%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

omron nx701-1600_firmware Use of Hard-coded Credentials

Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained th

CWE-294CWE-798Jul 4, 2022
CVSS9.4v3.1EPSS1.33%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Rockwell Automation Studio 5000 Logix Designer Code Injection

Omron CX-Position (versions 2.5.3 and prior) is vulnerable to multiple stack-based buffer overflow conditions while parsing a specific project file, which may allow an attacker to locally execute arbitrary code.

CWE-121CWE-787Apr 1, 2022
CVSS7.8v3.1EPSS1.98%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Rockwell Automation Studio 5000 Logix Designer Out-of-Bounds Write

Omron CX-Position (versions 2.5.3 and prior) is vulnerable to an out-of-bounds write while processing a specific project file, which may allow an attacker to execute arbitrary code.

CWE-787Apr 1, 2022
CVSS7.8v3.1EPSS1.41%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Rockwell Automation Studio 5000 Logix Designer Use After Free

Omron CX-Position (versions 2.5.3 and prior) is vulnerable to a use after free memory condition while processing a specific project file, which may allow an attacker to execute arbitrary code.

CWE-416Apr 1, 2022
CVSS7.8v3.1EPSS1.41%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Rockwell Automation Studio 5000 Logix Designer Improper Restriction of Operations within the Bounds of a Memory Buffer

Omron CX-Position (versions 2.5.3 and prior) is vulnerable to memory corruption while processing a specific project file, which may allow an attacker to execute arbitrary code.

CWE-119CWE-787Apr 1, 2022
CVSS7.8v3.1EPSS1.38%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Omron CX-One

Omron CX-One Versions 4.60 and prior are vulnerable to a stack-based buffer overflow while processing specific project files, which may allow an attacker to execute arbitrary code.

CWE-121CWE-787Jan 14, 2022
CVSS7.8v3.1EPSS9.27%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Omron CX-One

This vulnerability allows local attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type-confusion condition in the Omron CX-One Version 4.60 and prior devices.

CWE-843Feb 9, 2021
CVSS7.8v3.1EPSS1.78%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Omron CX-One

The Omron CX-One Version 4.60 and prior is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code.

CWE-121CWE-787Feb 9, 2021
CVSS8.8v3.1EPSS7.61%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Omron CX-One

The Omron CX-One Version 4.60 and prior may allow an attacker to supply a pointer to arbitrary memory locations, which may allow an attacker to remotely execute arbitrary code.

CWE-822Feb 9, 2021
CVSS8.8v3.1EPSS2.67%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Omron’s CS and CJ series PLCs have an unrestricted externally accessible lock vulnerability.

CWE-412Dec 16, 2019
CVSS9.8v3.1EPSS1.05%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

When processing project files, the application (Omron CX-Programmer v9.70 and prior and Common Components January 2019 and prior) fails to check if it is referencing freed memory. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.

CWE-416Apr 10, 2019
CVSS6.6v3.0EPSS1.15%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Three type confusion vulnerabilities exist in CX-One Versions 4.50 and prior and CX-Protocol Versions 2.0 and prior when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.

CWE-704CWE-843Jan 30, 2019
CVSS7.8v3.0EPSS1.42%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

When processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior and tampering with a specific byte, memory corruption may occur within a specific object.

CWE-119Nov 5, 2018
CVSS7.8v3.0EPSS1.07%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX