CVE-2013-3959

SIMATIC PCS7 < 8.0 and WinCC < 7.2 - Authenticated User Enumeration via Web Navigator NetBIOS URL Parameter

Title source: llm
STIX 2.1

Description

The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters.

References (1)

Core 1

Scores

EPSS 0.0016
EPSS Percentile 36.8%

Details

CWE
CWE-200
Status published
Products (5)
siemens/simatic_pcs7 8.0
siemens/simatic_pcs7 < 8.0
siemens/wincc 7.0 (4 CPE variants)
siemens/wincc 7.1 (2 CPE variants)
siemens/wincc < 7.2
Published Jun 14, 2013
Tracked Since Feb 18, 2026