Description
Omron CX-One CX-Programmer before 9.6 uses a reversible format for password storage in project source-code files, which makes it easier for local users to obtain sensitive information by reading a file.
References (1)
Core 1
Core References
Third Party Advisory, US Government Resource x_refsource_misc
https://ics-cert.us-cert.gov/advisories/ICSA-15-274-01
Scores
EPSS
0.0033
EPSS Percentile
25.4%
Details
CWE
CWE-200
Status
published
Products (1)
omron/cx-programmer
< 9.5
Published
Oct 06, 2015
Tracked Since
Feb 18, 2026