CVE-2015-1358

Siemens SIMATIC WinCC <13 SP1 - Info Disclosure

Title source: llm
STIX 2.1

Description

The remote-management module in the (1) Multi Panels, (2) Comfort Panels, and (3) RT Advanced functionality in Siemens SIMATIC WinCC (TIA Portal) before 13 SP1 and in the (4) panels and (5) runtime functionality in SIMATIC WinCC flexible before 2008 SP3 Up7 does not properly encrypt credentials in transit, which makes it easier for remote attackers to determine cleartext credentials by sniffing the network and conducting a decryption attack.

References (5)

Core 5
Core References
US Government Resource x_refsource_misc
https://ics-cert.us-cert.gov/advisories/ICSA-16-161-02
Third Party Advisory, VDB Entry vdb-entry x_refsource_bid
http://www.securityfocus.com/bid/72625
Third Party Advisory, VDB Entry vdb-entry x_refsource_sectrack
http://www.securitytracker.com/id/1036090

Scores

EPSS 0.0080
EPSS Percentile 74.2%

Details

CWE
CWE-310
Status published
Products (1)
siemens/wincc 13.0
Published Feb 18, 2015
Tracked Since Feb 18, 2026