CVE-2016-8673

HIGH

SIMATIC CP/S7-300/S7-400 <3.0.53/<2.17 - RCE

Title source: llm
STIX 2.1

Description

A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.0.53), SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.2.17), SIMATIC S7-300 PN/DP CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP CPU family (incl. SIPLUS variants) (All versions). The integrated web server at port 80/TCP or port 443/TCP of the affected devices could allow remote attackers to perform actions with the permissions of an authenticated user, provided the targeted user has an active session and is induced to trigger the malicious request.

References (1)

Core 1
Core References

Scores

CVSS v3 8.8
EPSS 0.0014
EPSS Percentile 33.1%
Attack Vector NETWORK
CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Details

CWE
CWE-352
Status published
Products (4)
siemens/simatic_cp_343-1_firmware
siemens/simatic_cp_443-1_firmware
siemens/simatic_s7_300_cpu_firmware
siemens/simatic_s7_400_cpu_firmware
Published Nov 23, 2016
Tracked Since Feb 18, 2026