CVE-2018-11460

HIGH

SINUMERIK < V4.7 SP6 HF1, < V4.8 SP3 - Local Privilege Escalation

Title source: llm
STIX 2.1

Description

A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with elevated user privileges (manufact) could modify a CRAMFS archive so that after reboot the system loads the modified CRAMFS file and attacker-controlled code is executed with root privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires elevated user privileges (manufact) but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.

References (2)

Core 2
Core References
Third Party Advisory, VDB Entry vdb-entry x_refsource_bid
http://www.securityfocus.com/bid/106185

Scores

CVSS v3 7.8
EPSS 0.0004
EPSS Percentile 13.5%
Attack Vector LOCAL
CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Details

CWE
CWE-693
Status published
Products (5)
siemens/sinumerik_808d_v4.7_firmware
siemens/sinumerik_808d_v4.8_firmware
siemens/sinumerik_828d_v4.7_firmware < 4.7
siemens/sinumerik_840d_sl_v4.7_firmware < 4.7
siemens/sinumerik_840d_sl_v4.8_firmware < 4.8
Published Dec 12, 2018
Tracked Since Feb 18, 2026