CVE-2019-10332

MEDIUM

Jenkins ElectricFlow < 1.1.5 - Missing Authorization in Configuration Connection Test

Title source: llm
STIX 2.1

Description

A missing permission check in Jenkins ElectricFlow Plugin 1.1.5 and earlier in Configuration#doTestConnection allowed users with Overall/Read access to connect to an attacker-specified URL using attacker-specified credentials.

References (3)

Core 3
Core References
Mailing List, Third Party Advisory mailing-list x_refsource_mlist
http://www.openwall.com/lists/oss-security/2019/06/11/1
Third Party Advisory, VDB Entry vdb-entry x_refsource_bid
http://www.securityfocus.com/bid/108747

Scores

CVSS v3 4.3
EPSS 0.0012
EPSS Percentile 30.8%
Attack Vector NETWORK
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N

Details

CWE
CWE-862
Status published
Products (2)
jenkins/electricflow < 1.1.5
org.jenkins-ci.plugins/electricflow 0 - 1.1.7Maven
Published Jun 11, 2019
Tracked Since Feb 18, 2026