CVE-2019-13924

MEDIUM

SCALANCE X-200 and X-300 Firmware - Clickjacking via Missing X-Frame-Options Header

Title source: llm
STIX 2.1

Description

A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.

Scores

CVSS v3 5.4
EPSS 0.0027
EPSS Percentile 50.6%
Attack Vector NETWORK
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N

Details

CWE
CWE-1021 CWE-693
Status published
Products (8)
siemens/scalance_x-200irt_firmware
siemens/scalance_x-300_firmware < 4.1.3
siemens/scalance_xb-200_firmware < 5.2.4
siemens/scalance_xc-200_firmware < 5.2.4
siemens/scalance_xf-200_firmware < 5.2.4
siemens/scalance_xp-200_firmware < 5.2.4
siemens/scalance_xr-300_firmware < 4.1.3
siemens/scalance_xr-300wg_firmware < 4.1.3
Published Feb 11, 2020
Tracked Since Feb 18, 2026