CVE-2019-18337
CRITICALSINVR 3 Central Control Server < V1.5.0 - Authentication Bypass via XML Communication Protocol
Title source: llmDescription
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an authentication bypass vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. A remote attacker with network access to the CCS server could exploit this vulnerability to read the CCS users database, including the passwords of all users in obfuscated cleartext.
References (2)
Core 2
Core References
Vendor Advisory x_refsource_misc
https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf
Vendor Advisory x_refsource_confirm
https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf
Scores
CVSS v3
9.8
EPSS
0.0007
EPSS Percentile
22.4%
Attack Vector
NETWORK
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CISA SSVC
Vulnrichment
Exploitation
none
Automatable
yes
Technical Impact
total
Details
CWE
CWE-287
Status
published
Products (2)
siemens/sinvr_3_central_control_server
siemens/sinvr_3_video_server
Published
Dec 12, 2019
Tracked Since
Feb 18, 2026