CVE-2019-19292

HIGH

Control Center Server < V1.5.0 - SQL Injection

Title source: llm
STIX 2.1

Description

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an SQL injection vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. An authenticated remote attacker could exploit this vulnerability to read or modify the CCS database and potentially execute administrative database operations or operating system commands.

References (2)

Core 2
Core References
Mitigation, Vendor Advisory x_refsource_misc
https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf

Scores

CVSS v3 8.8
EPSS 0.0055
EPSS Percentile 68.3%
Attack Vector NETWORK
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Details

CWE
CWE-89
Status published
Products (2)
siemens/sinvr_3_central_control_server
siemens/sinvr_3_video_server
Published Mar 10, 2020