CVE-2020-10270

CRITICAL

MiR Fleet Firmware < 2.8.1.1 - Use of Hard-coded Credentials

Title source: llm
STIX 2.1

Description

Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users (omitted) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. This flaw allows cyber attackers to take control of the robot remotely and make use of the default user interfaces MiR has created, lowering the complexity of attacks and making them available to entry-level attackers. More elaborated attacks can also be established by clearing authentication and sending network requests directly. We have confirmed this flaw in MiR100 and MiR200 but according to the vendor, it might also apply to MiR250, MiR500 and MiR1000.

References (1)

Core 1
Core References
Exploit, Third Party Advisory x_refsource_confirm
https://github.com/aliasrobotics/RVD/issues/2557

Scores

CVSS v3 9.8
EPSS 0.0166
EPSS Percentile 73.5%
Attack Vector NETWORK
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Details

CWE
CWE-798
Status published
Products (10)
aliasrobotics/mir1000_firmware < 2.8.1.1
aliasrobotics/mir100_firmware < 2.8.1.1
aliasrobotics/mir200_firmware < 2.8.1.1
aliasrobotics/mir250_firmware < 2.8.1.1
aliasrobotics/mir500_firmware < 2.8.1.1
enabled-robotics/er-flex_firmware < 2.8.1.1
enabled-robotics/er-lite_firmware < 2.8.1.1
enabled-robotics/er-one_firmware < 2.8.1.1
mobile-industrial-robotics/er200_firmware < 2.8.1.1
uvd-robots/uvd_robots_firmware < 2.8.1.1
Published Jun 24, 2020
Tracked Since Feb 18, 2026