Description

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products.

References (1)

Core 1
Core References

Scores

CVSS v3 6.5
EPSS 0.0049
EPSS Percentile 65.5%
Attack Vector NETWORK
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H

Details

CWE
CWE-306
Status published
Products (50)