CVE-2020-7589

CRITICAL

Siemens LOGO! 8 BM Firmware - Unauthenticated Configuration Read/Write via Port 135/tcp

Title source: llm
STIX 2.1

Description

A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions). The vulnerability could lead to an attacker reading and modifying the device configuration and obtain project files from affected devices. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 135/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

References (2)

Core 2
Core References
Third Party Advisory, US Government Resource x_refsource_misc
https://www.us-cert.gov/ics/advisories/icsa-20-161-03

Scores

CVSS v3 9.1
EPSS 0.0047
EPSS Percentile 64.9%
Attack Vector NETWORK
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N

Details

CWE
CWE-306
Status published
Products (1)
siemens/logo\!_8_bm_firmware
Published Jun 10, 2020
Tracked Since Feb 18, 2026