CVE-2021-27475
HIGHRockwellautomation Connected Components Workbench < 12.00.00 - Insecure Deserialization
Title source: ruleDescription
Rockwell Automation Connected Components Workbench v12.00.00 and prior does not limit the objects that can be deserialized. This vulnerability allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in remote code execution. This vulnerability requires user interaction to be successfully exploited.
Scores
CVSS v3
8.6
EPSS
0.0021
EPSS Percentile
42.4%
Attack Vector
LOCAL
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H
Classification
CWE
CWE-502
Status
published
Affected Products (1)
rockwellautomation/connected_components_workbench
< 12.00.00
Timeline
Published
Mar 23, 2022
Tracked Since
Feb 18, 2026