CVE-2021-36705
CRITICALProLink PRC2402M Firmware < 1.0.18 - OS Command Injection via TR069_local_port Parameter
Title source: llmDescription
In ProLink PRC2402M V1.0.18 and older, the set_TR069 function in the adm.cgi binary, accessible with a page parameter value of TR069 contains a trivial command injection where the value of the TR069_local_port parameter is passed directly to system.
References (1)
Core 1
Core References
Exploit, Third Party Advisory x_refsource_misc
https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#tr069-command-injection
Scores
CVSS v3
9.8
EPSS
0.0262
EPSS Percentile
83.5%
Attack Vector
NETWORK
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Details
CWE
CWE-78
Status
published
Products (1)
prolink/prc2402m_firmware
< 1.0.18
Published
Aug 06, 2021
Tracked Since
Feb 18, 2026