CVE-2021-38390

CRITICAL

Delta Electronics DIAEnergie <1.7.5 - SQL Injection

Title source: llm
STIX 2.1

Description

A Blind SQL injection vulnerability exists in the /DataHandler/HandlerEnergyType.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter egyid before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\MSSQLSERVER.

References (1)

Core 1
Core References
Third Party Advisory, US Government Resource x_refsource_misc
https://us-cert.cisa.gov/ics/advisories/icsa-21-238-03

Scores

CVSS v3 9.8
EPSS 0.0165
EPSS Percentile 82.2%
Attack Vector NETWORK
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Details

CWE
CWE-89
Status published
Products (1)
deltaww/diaenergie < 1.7.5
Published Aug 30, 2021
Tracked Since Feb 18, 2026