CVE-2022-31810

HIGH

SiPass integrated < 2.90.3.8 - Unauthenticated Denial of Service via Configuration Client Login Packet

Title source: llm
STIX 2.1

Description

A vulnerability has been identified in SiPass integrated (All versions < V2.90.3.8). Affected server applications improperly check the size of data packets received for the configuration client login, causing a stack-based buffer overflow. This could allow an unauthenticated remote attacker to crash the server application, creating a denial of service condition.

References (1)

Core 1

Scores

CVSS v3 7.5
EPSS 0.0054
EPSS Percentile 67.7%
Attack Vector NETWORK
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

CISA SSVC

Vulnrichment
Exploitation none
Automatable yes
Technical Impact partial

Details

CWE
CWE-20 CWE-787
Status published
Products (1)
siemens/sipass_integrated < 2.90.3.8
Published Jul 11, 2023