Description
Linux disk/nic frontends data leaks T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Linux Block and Network PV device frontends don't zero memory regions before sharing them with the backend (CVE-2022-26365, CVE-2022-33740). Additionally the granularity of the grant table doesn't allow sharing less than a 4K page, leading to unrelated data residing in the same 4K page as data shared with a backend being accessible by such backend (CVE-2022-33741, CVE-2022-33742).
References (7)
Scores
CVSS v3
7.1
EPSS
0.0003
EPSS Percentile
9.2%
Attack Vector
LOCAL
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H
Details
CWE
CWE-212
Status
published
Products (8)
debian/debian_linux
10.0
debian/debian_linux
11.0
fedoraproject/fedora
35
fedoraproject/fedora
36
linux/linux_kernel
2.6.12 rc2 (5 CPE variants)
linux/linux_kernel
5.19 rc1 (5 CPE variants)
linux/linux_kernel
2.6.13 - 4.9.322
xen/xen
Published
Jul 05, 2022
Tracked Since
Feb 18, 2026