cert-portal.siemens.com
https://cert-portal.siemens.com/productcert/html/ssa-585531.html CVE-2022-37660
MEDIUM
Record summary
CVE-2022-37660 has a selected CVSS score of 6.5 (medium).
Description
In hostapd 2.10 and earlier, the PKEX code remains active even after a successful PKEX association. An attacker that successfully bootstrapped public keys with another entity using PKEX in the past, will be able to subvert a future bootstrapping by passively observing public keys, re-using the encrypting element Qi and subtracting it from the captured message M (X = M - Qi). This will result in the public ephemeral key X; the only element required to subvert the PKEX association.
Description source: CVE List
Exploitation context
CISA SSVC decision
ExploitationNone
AutomatableYes
Technical impactPartial
CISA Coordinator · SSVC 2.0.3 · Evaluated Feb 13, 2025 · Source: CVE List
Affected products and versions
1| Product | Source | Version range | Status |
|---|---|---|---|
SIDIS Secured SmartPlugBrowse Siemens / SIDIS Secured SmartPlugDefault status: unknown | CVE List | Before V7.26.0310 | affected |
References
5link.springer.com
https://link.springer.com/article/10.1007/s10207-025-00988-3 lists.debian.org
https://lists.debian.org/debian-lts-announce/2025/04/msg00019.html nvd.nist.gov
https://nvd.nist.gov/vuln/detail/CVE-2022-37660 w1.fi
https://w1.fi/cgit/hostap/commit?id=15af83cf1846870873a011ed4d714732f01cd2e4