CVE-2022-39157

HIGH

Siemens Parasolid < 34.0.254 - Out-of-Bounds Read

Title source: rule
STIX 2.1

Description

A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.0 (All versions >= V34.0.252 < V34.0.254), Parasolid V34.1 (All versions < V34.1.242), Parasolid V34.1 (All versions >= V34.1.242 < V34.1.244), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.0 (All versions >= V35.0.170 < V35.0.184), Simcenter Femap (All versions < V2023.1). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17745)

Scores

CVSS v3 7.8
EPSS 0.0006
EPSS Percentile 19.2%
Attack Vector LOCAL
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

CISA SSVC

Vulnrichment
Exploitation none
Automatable no
Technical Impact total

Details

CWE
CWE-125
Status published
Products (1)
siemens/parasolid 34.0.252 - 34.0.254
Published Nov 08, 2022
Tracked Since Feb 18, 2026