CVE-2022-41629

HIGH

Delta Electronics InfraSuite Device Master <00.00.01a - Info Disclo...

Title source: llm
STIX 2.1

Description

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.

References (1)

Core 1
Core References
Patch, Third Party Advisory, US Government Resource government-resource
https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07

Scores

CVSS v3 7.5
EPSS 0.0026
EPSS Percentile 49.4%
Attack Vector NETWORK
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

CISA SSVC

Vulnrichment
Exploitation none
Automatable yes
Technical Impact partial

Details

CWE
CWE-306
Status published
Products (1)
deltaww/infrasuite_device_master < 00.00.02a
Published Oct 31, 2022
Tracked Since Feb 18, 2026