Description
Password recovery vulnerability in SICK SIM2000ST Partnumber 2086502 with firmware version <1.13.4 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.13.4 as soon as possible (available in SICK Support Portal).
References (1)
Scores
CVSS v3
9.8
EPSS
0.0075
EPSS Percentile
73.3%
Attack Vector
NETWORK
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CISA SSVC
Vulnrichment
Exploitation
none
Automatable
yes
Technical Impact
total
Details
CWE
CWE-306
CWE-640
Status
published
Products (1)
sick/sim2000_firmware
< 1.13.4
Published
Dec 16, 2022
Tracked Since
Feb 18, 2026