Description
Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a remote code execution (RCE) vulnerability via manipulated parameters of the web interface without authentication. This could lead to a full compromise of the FDS101 device.
References (1)
Core 1
Core References
Third Party Advisory
https://cert.vde.com/en/advisories/VDE-2023-038
Scores
CVSS v3
9.8
EPSS
0.0100
EPSS Percentile
58.6%
Attack Vector
NETWORK
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CISA SSVC
Vulnrichment
Exploitation
none
Automatable
yes
Technical Impact
total
Details
CWE
CWE-94
Status
published
Products (1)
frauscher/frauscher_diagnostic_system_101
< 1.4.24 (2 CPE variants)
Published
Sep 21, 2023
Tracked Since
Feb 18, 2026