Description
Voltronic Power ViewPower USBCommEx shutdown Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Voltronic Power ViewPower Pro. User interaction is required to exploit this vulnerability in that an administrator must trigger a shutdown operation. The specific flaw exists within the shutdown method. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22065.
Scores
CVSS v3
8.8
EPSS
0.0101
EPSS Percentile
77.2%
Attack Vector
NETWORK
CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CISA SSVC
Vulnrichment
Exploitation
none
Automatable
no
Technical Impact
total
Details
CWE
CWE-749
Status
published
Products (1)
voltronicpower/viewpower
1.04.21353
Published
May 03, 2024
Tracked Since
Feb 18, 2026