CVE-2024-41986

MEDIUM

Siemens Opcenter Quality - Broken Cryptographic Algorithm

Title source: rule
STIX 2.1

Description

A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application support insecure TLS 1.0 and 1.1 protocol. An attacker could achieve a man-in-the-middle attack and compromise confidentiality and integrity of data.

Scores

CVSS v3 6.4
EPSS 0.0001
EPSS Percentile 1.6%
Attack Vector ADJACENT_NETWORK
CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:L

CISA SSVC

Vulnrichment
Exploitation none
Automatable no
Technical Impact partial

Details

CWE
CWE-327
Status published
Products (1)
siemens/opcenter_quality 13.2
Published Aug 12, 2025
Tracked Since Feb 18, 2026