Description
UltiMaker Cura slicer versions 5.7.0-beta.1 through 5.7.2 are vulnerable to code injection via the 3MF format reader (/plugins/ThreeMFReader.py). The vulnerability arises from improper handling of the drop_to_buildplate property within 3MF files, which are ZIP archives containing the model data. When a 3MF file is loaded in Cura, the value of the drop_to_buildplate property is passed to the Python eval() function without proper sanitization, allowing an attacker to execute arbitrary code by crafting a malicious 3MF file. This vulnerability poses a significant risk as 3MF files are commonly shared via 3D model databases.
References (1)
Core 1
Scores
CVSS v3
7.8
EPSS
0.0043
EPSS Percentile
34.6%
Attack Vector
LOCAL
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CISA SSVC
Vulnrichment
Exploitation
none
Automatable
no
Technical Impact
total
Details
CWE
CWE-94
Status
published
Products (4)
ultimaker/ultimaker_cura
5.7.0 (2 CPE variants)
ultimaker/ultimaker_cura
5.7.1
ultimaker/ultimaker_cura
5.7.2 rc2
ultimaker/ultimaker_cura
5.8.0 beta1 (3 CPE variants)
Published
Sep 03, 2024
Tracked Since
Feb 18, 2026