CVE-2025-30645

HIGH

Juniper Junos OS SRX Series DoS via DS-Lite Tunnel Control Traffic

Title source: llm
STIX 2.1

Description

A NULL Pointer Dereference vulnerability in the flow daemon (flowd) of Juniper Networks Junos OS on SRX Series allows an attacker causing specific, valid control traffic to be sent out of a Dual-Stack (DS) Lite tunnel to crash the flowd process, resulting in a Denial of Service (DoS).  Continuous triggering of specific control traffic will create a sustained Denial of Service (DoS) condition. On all SRX platforms, when specific, valid control traffic needs to be sent out of a DS-Lite tunnel, a segmentation fault occurs within the flowd process, resulting in a network outage until the flowd process restarts. This issue affects Junos OS on SRX Series: * All versions before 21.2R3-S9, * from 21.4 before 21.4R3-S9, * from 22.2 before 22.2R3-S5, * from 22.4 before 22.4R3-S6, * from 23.2 before 23.2R2-S3, * from 23.4 before 23.4R2.

References (1)

Core 1
Core References
Vendor Advisory vendor-advisory
https://supportportal.juniper.net/JSA96455

Scores

CVSS v3 7.5
EPSS 0.0040
EPSS Percentile 60.6%
Attack Vector NETWORK
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

CISA SSVC

Vulnrichment
Exploitation none
Automatable yes
Technical Impact partial

Details

CWE
CWE-476
Status published
Products (4)
juniper/junos 21.2 (16 CPE variants)
juniper/junos 21.4 (16 CPE variants)
juniper/junos 22.2 (12 CPE variants)
juniper/junos 22.4 (6 CPE variants)
Published Apr 09, 2025
Tracked Since Feb 18, 2026