CVE-2025-32825

HIGH

TeleControl Server Basic < 3.1.2.2 - Authenticated SQL Injection via GetProjects Method

Title source: llm
STIX 2.1

Description

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetProjects' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

References (1)

Core 1

Scores

CVSS v3 8.8
EPSS 0.0100
EPSS Percentile 77.3%
Attack Vector NETWORK
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

CISA SSVC

Vulnrichment
Exploitation none
Automatable no
Technical Impact total

Details

CWE
CWE-89
Status published
Products (1)
siemens/telecontrol_server_basic < 3.1.2.2
Published Apr 16, 2025
Tracked Since Feb 18, 2026