CVE-2025-5022

MEDIUM

Mitsubishi Electric Corporation photovoltaic system monitor - Info ...

Title source: llm
STIX 2.1

Description

Weak Password Requirements vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to derive the password from the SSID. In addition, if the product is configured to enable the individual air conditioner control function, an attacker who has access to the Wi-Fi communication between the units by exploiting this vulnerability may be able to execute ECHONET Lite commands to perform operations such as turning the air conditioner on or off and changing the set temperature. The individual air conditioner control function is available only in display unit version 02.00.01 or later and measurement unit version 02.03.01 or later. The affected products discontinued in 2015, support ended in 2020.

Scores

CVSS v3 6.5
EPSS 0.0003
EPSS Percentile 10.1%
Attack Vector ADJACENT_NETWORK
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

CISA SSVC

Vulnrichment
Exploitation none
Automatable no
Technical Impact partial

Details

CWE
CWE-521
Status published
Products (2)
Mitsubishi Electric Corporation/PV-DR004J All versions
Mitsubishi Electric Corporation/PV-DR004JA All versions
Published Jul 10, 2025
Tracked Since Feb 18, 2026