CVE-2025-5023

HIGH

Mitsubishi Electric Corporation photovoltaic system monitor - Info ...

Title source: llm
STIX 2.1

Description

Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to disclose information such as generated power and electricity sold back to the grid stored in the product, tamper with or destroy stored or configured information in the product, or cause a Denial-of-Service (DoS) condition on the product, by using hardcoded user ID and password common to the product series obtained by exploiting CVE-2025-5022. The affected products discontinued in 2015, support ended in 2020.

Scores

CVSS v3 7.1
EPSS 0.0003
EPSS Percentile 6.8%
Attack Vector ADJACENT_NETWORK
CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:H/A:H

CISA SSVC

Vulnrichment
Exploitation none
Automatable no
Technical Impact total

Details

CWE
CWE-798
Status published
Products (2)
Mitsubishi Electric Corporation/PV-DR004J All versions
Mitsubishi Electric Corporation/PV-DR004JA All versions
Published Jul 10, 2025
Tracked Since Feb 18, 2026