Description
An unauthenticated user can connect to a publicly accessible database using arbitrary credentials. The system grants full access to the database by leveraging a previously authenticated connection through a "mmBackup" application. This flaw allows attackers to bypass authentication mechanisms and gain unauthorized access to database with sensitive data. This issue affects Asseco mMedica in versions before 11.9.5.
References (2)
Core 2
Core References
Various Sources third-party-advisory
https://cert.pl/en/posts/2025/10/CVE-2025-9313/
Various Sources product
https://mmedica.asseco.pl/
Scores
CVSS v4
9.3
EPSS
0.0047
EPSS Percentile
36.9%
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CISA SSVC
Vulnrichment
Exploitation
none
Automatable
yes
Technical Impact
total
Details
CWE
CWE-288
Status
published
Products (1)
Asseco Poland S.A./mMedica
< 11.9.5
Published
Oct 28, 2025
Tracked Since
Feb 18, 2026