CVE-2026-20204

HIGH

Improper Handling and Insufficient Isolation of Specific Temporary Files in Splunk Enterprise

Title source: cna
STIX 2.1

Description

In Splunk Enterprise versions below 10.2.1, 10.0.5, 9.4.10, and 9.3.11, and Splunk Cloud Platform versions below 10.4.2603.0, 10.3.2512.5, 10.2.2510.9, 10.1.2507.19, 10.0.2503.13, and 9.3.2411.127, a low-privileged user that does not hold the `admin` or `power` Splunk roles could potentially perform a Remote Code Execution (RCE) by uploading a malicious file to the `$SPLUNK_HOME/var/run/splunk/apptemp` directory due to improper handling and insufficient isolation of temporary files within the `apptemp` directory.

Scores

CVSS v3 7.1
EPSS 0.0018
EPSS Percentile 39.8%
Attack Vector NETWORK
CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H

CISA SSVC

Vulnrichment
Exploitation none
Automatable no
Technical Impact total

Details

CWE
CWE-377
Status published
Products (13)
splunk/splunk 10.2.0
splunk/splunk 9.3.0 - 9.3.11
Splunk/Splunk Cloud Platform 10.0.2503 - 10.0.2503.13
Splunk/Splunk Cloud Platform 10.1.2507 - 10.1.2507.19
Splunk/Splunk Cloud Platform 10.2.2510 - 10.2.2510.9
Splunk/Splunk Cloud Platform 10.3.2512 - 10.3.2512.5
Splunk/Splunk Cloud Platform 10.4.2603 - Not Affected
Splunk/Splunk Cloud Platform 9.3.2411 - 9.3.2411.127
Splunk/Splunk Enterprise 10.0 - 10.0.5
Splunk/Splunk Enterprise 10.2 - 10.2.1
... and 3 more
Published Apr 15, 2026
Tracked Since Apr 15, 2026