CVE-2026-31965

HIGH

HTSlib CRAM reader has out-of-bounds reads due to improper validation of input

Title source: cna
STIX 2.1

Description

HTSlib is a library for reading and writing bioinformatics file formats. CRAM is a compressed format which stores DNA sequence alignment data. In the `cram_decode_slice()` function called while reading CRAM records, validation of the reference id field occurred too late, allowing two out of bounds reads to occur before the invalid data was detected. The bug does allow two values to be leaked to the caller, however as the function reports an error it may be difficult to exploit them. It is also possible that the program will crash due to trying to access invalid memory. Versions 1.23.1, 1.22.2 and 1.21.1 include fixes for this issue. There is no workaround for this issue.

Scores

CVSS v3 8.2
EPSS 0.0002
EPSS Percentile 5.0%
Attack Vector NETWORK
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H

CISA SSVC

Vulnrichment
Exploitation none
Automatable yes
Technical Impact partial

Details

CWE
CWE-125 CWE-129
Status published
Products (5)
htslib/htslib 1.23
htslib/htslib < 1.21.1
samtools/htslib < 1.21.1
samtools/htslib = 1.23
samtools/htslib >= 1.22, < 1.22.2
Published Mar 18, 2026
Tracked Since Mar 19, 2026