CVE-2026-34021
HIGHLack of cryptographic protection in Wertheim SafeController 5400 enables RS-485 message sniffing and replay
Title source: cnaDescription
The Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320, uses RS-485 communication between the server and the microcontroller without cryptographic protection. An attacker with access to the communication path between the server and the microcontroller can sniff RS-485 messages and replay previously observed messages. This can be used, for example, to spoof a "quit alarm" message and continuously deactivate the safe alarm.
References (3)
Core 3
Core References
Product product
https://wertheim-safes.com/safe-deposit-boxes/
Third Party Advisory third-party-advisory
https://r.sec-consult.com/wertdev
Scores
CVSS v4
8.6
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CISA SSVC
Vulnrichment
Exploitation
poc
Automatable
no
Technical Impact
total
Details
CWE
CWE-294
Status
published
Products (1)
Wertheim GmbH/Wertheim SafeController 5400 Hardware for VAULT ROOMS (Safe Deposit Locker System - Microcontroller)
Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320
Published
Jun 15, 2026
Tracked Since
Jun 15, 2026