CVE-2026-41173

MEDIUM

Unbounded HTTP response body read in OpenTelemetry.Sampler.AWS

Title source: cna
STIX 2.1

Description

The AWS X-Ray Remote Sampler package provides a sampler which can get sampling configurations from AWS X-Ray. Prior to 0.1.0-alpha.8, OpenTelemetry.Sampler.AWS reads unbounded HTTP response bodies from a configured AWS X-Ray remote sampling endpoint into memory. AWSXRaySamplerClient.DoRequestAsync called HttpClient.SendAsync followed by ReadAsStringAsync(), which materializes the entire HTTP response body into a single in-memory string with no size limit. The sampling endpoint is configurable via AWSXRayRemoteSamplerBuilder.SetEndpoint (default: http://localhost:2000). An attacker who controls the configured endpoint, or who can intercept traffic to it (MitM), can return an arbitrarily large response body. This causes unbounded heap allocation in the consuming process, leading to high transient memory pressure, garbage-collection stalls, or an OutOfMemoryException that terminates the process. This vulnerability is fixed in 0.1.0-alpha.8.

Scores

CVSS v3 5.9
EPSS 0.0002
EPSS Percentile 3.8%
Attack Vector NETWORK
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H

CISA SSVC

Vulnrichment
Exploitation none
Automatable no
Technical Impact partial

Details

CWE
CWE-770
Status published
Products (3)
nuget/OpenTelemetry.Resources.AWS 0 - 1.15.1NuGet
nuget/OpenTelemetry.Sampler.AWS 0 - 0.1.0-alpha.8NuGet
open-telemetry/opentelemetry-dotnet-contrib < 0.1.0-alpha.8
Published Apr 23, 2026