CVE-2026-5397

HIGH

Vulnerability Related to an Uncontrolled Search Path Element in a UPS Management Application

Title source: cna
STIX 2.1

Description

It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that is then executed with administrator privileges. If a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL may be executed by exploiting the product’s behavior of loading missing DLLs from the same directory as the executable during service startup.

Scores

CVSS v3 7.8
EPSS 0.0001
EPSS Percentile 1.7%
Attack Vector LOCAL
CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H

CISA SSVC

Vulnrichment
Exploitation none
Automatable no
Technical Impact total

Details

CWE
CWE-427
Status published
Products (1)
OMRON SOCIAL SOLUTIONS CO., Ltd./PowerAttendant Standard Edition 2.1.2 or lower
Published Apr 15, 2026
Tracked Since Apr 15, 2026