CVE-2026-6992
HIGHLinksys MR9600 JNAP Action run_central2.sh BTRequestGetSmartConnectStatus os command injection
Title source: cnaDescription
A vulnerability was identified in Linksys MR9600 2.0.6.206937. This affects the function BTRequestGetSmartConnectStatus of the file /etc/init.d/run_central2.sh of the component JNAP Action Handler. The manipulation of the argument pin leads to os command injection. The attack may be initiated remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
Scores
CVSS v3
7.2
EPSS
0.0012
EPSS Percentile
31.0%
Attack Vector
NETWORK
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
CISA SSVC
Vulnrichment
Exploitation
poc
Automatable
no
Technical Impact
total
Details
CWE
CWE-77
CWE-78
Status
published
Products (1)
Linksys/MR9600
2.0.6.206937
Published
Apr 25, 2026
Tracked Since
Apr 26, 2026