CVE-2026-9108
MEDIUMRockwell Studio 5000 Logix Designer - ACD Project Path Traversal
Title source: manualDescription
A path traversal security issue exists within Studio 5000 Logix Designer® due to improper limitation of file paths within ACD project files. The software does not sanitize or validate file names embedded in the ACD file structure during the project opening procedure, allowing path traversal sequences to escape the intended extraction directory. If exploited, an attacker could craft a malicious ACD project file that results in arbitrary files being written to attacker-controlled locations on the file system, potentially leading to code execution.
References (1)
Core 1
Scores
CVSS v4
5.4
EPSS
0.0011
EPSS Percentile
1.5%
CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CISA SSVC
Vulnrichment
Exploitation
none
Automatable
no
Technical Impact
total
Details
CWE
CWE-22
Status
published
Products (1)
Rockwell Automation/Studio 5000 Logix Designer
V36.00, 35.00,35.01, 34.00-34.03, 33.00-33.03, 32.00-32.04 and older
Published
Jul 14, 2026
Tracked Since
Jul 14, 2026