EIP-2026-101301

PRE-CVE

HomeMatic Zentrale CCU2 - Remote Code Execution

Title source: legacy
STIX 2.1

Exploitation Summary

EIP tracks 1 public exploit for EIP-2026-101301. PoCs published by Kacper Szurek.

AI-analyzed exploit summary This exploit targets an unauthenticated RCE vulnerability in HomeMatic Zentrale CCU2 via improper input sanitization in the `session_logout` function. It injects TCL commands to enable SSH access and change the root password.

Description

HomeMatic Zentrale CCU2 - Remote Code Execution

Exploits (1)

exploitdb WORKING POC
by Kacper Szurek · pythonremotehardware
https://www.exploit-db.com/exploits/45052

This exploit targets an unauthenticated RCE vulnerability in HomeMatic Zentrale CCU2 via improper input sanitization in the `session_logout` function. It injects TCL commands to enable SSH access and change the root password.

Classification
Working Poc 100%
Attack Type
Rce
Complexity
Moderate
Reliability
Reliable
Target: HomeMatic Zentrale CCU2 (versions before 2.35.16)
No auth needed
Prerequisites: Network access to the target device · Target device must be running vulnerable HomeMatic CCU2 firmware
devstral-2 · analyzed Feb 16, 2026 Full analysis →

Details

Status pre_cve
Tracked Since Feb 18, 2026