EIP-2026-119338
PRE-CVEZScada Modbus Buffer 2.0 - Stack Buffer Overflow (Metasploit)
Title source: legacyExploitation Summary
EIP tracks 1 public exploit for EIP-2026-119338. PoCs published by James Fitts.
AI-analyzed exploit summary This Metasploit module exploits a stack-based buffer overflow in Z-Scada Net 2.0 by sending a crafted Modbus response packet. The exploit triggers a buffer overflow at offset 574, overwrites the return address with a 'jmp $+8' instruction, and executes the payload.
Description
ZScada Modbus Buffer 2.0 - Stack Buffer Overflow (Metasploit)
Exploits (1)
exploitdb
WORKING POC
by James Fitts · rubyremotewindows
https://www.exploit-db.com/exploits/42691
This Metasploit module exploits a stack-based buffer overflow in Z-Scada Net 2.0 by sending a crafted Modbus response packet. The exploit triggers a buffer overflow at offset 574, overwrites the return address with a 'jmp $+8' instruction, and executes the payload.
Classification
Working Poc 95%
Attack Type
Rce
Complexity
Moderate
Reliability
Reliable
Target:
Z-Scada Net 2.0
No auth needed
Prerequisites:
Network access to the target system on port 502 · Target running Z-Scada Net 2.0 on Windows XP SP3 EN
MITRE ATT&CK
devstral-2 · analyzed Feb 18, 2026
Full analysis →
Details
Status
pre_cve
Tracked Since
Feb 18, 2026