Endress+Hauser Vulnerabilities and Affected Products
Vulnerabilities associated with ORSG35 - Ecograph T Neutral/Private Label.
Products
Clear product- Endress+Hauser MEAC300-FNADE419 vulnerabilities
- ORSG35 - Ecograph T Neutral/Private Label2 vulnerabilities
- RSG35 - Ecograph T2 vulnerabilities
- Echo Curve Viewer1 vulnerability
- FDI Package library1 vulnerability
- Field Xpert SMT501 vulnerability
- Field Xpert SMT701 vulnerability
- Field Xpert SMT771 vulnerability
- Field Xpert SMT791 vulnerability
- FieldCare SFE500 Package USB1 vulnerability
- FieldCare SFE500 Package Web-Package1 vulnerability
- FLPS1 vulnerability
- GM321 vulnerability
- GMS8001 vulnerability
- GMS800 FIDOR1 vulnerability
- MARSIC2001 vulnerability
- MARSIC2801 vulnerability
- MARSIC3001 vulnerability
- MCS100FT1 vulnerability
- MCS200HW1 vulnerability
- MCS300P1 vulnerability
- MCU ETH-Service and Modbus-TCP Module1 vulnerability
- MERCEM300Z1 vulnerability
- MES1B B&B Converter1 vulnerability
- ORSG45 - Memograph M Neutral/Private Label1 vulnerability
| Vulnerability | Title and context | CVSS | EPSS | PoCs | Signals | STIX action |
|---|---|---|---|---|---|---|
CVE-2020-12496MEDIUM | ENDRESS+HAUSER: Ecograph T utilizing Webserver firmware version 2.x exposures sensitive information to an unauthorized actorEndress+Hauser Ecograph T (Neutral/Private Label) (RSG35, ORSG35) and Memograph M (Neutral/Private Label) (RSG45, ORSG45) with Firmware version V2.0.0 and above is prone to exposure of sensitive information to an unauthorized actor. The firmware release has a dynamic token for each request submitted to the server, which makes repeating requests and analysis complex enough. Nevertheless, it's possible and during the analysis it was discovered that it also has an issue with the access-control matr… CWE-200Nov 19, 2020 | CVSS6.5v3.1 | EPSS0.825% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2020-12495CRITICAL | ENDRESS+HAUSER: Ecograph T utilizing Webserver firmware version 1.x has improper privilege managementEndress+Hauser Ecograph T (Neutral/Private Label) (RSG35, ORSG35) with Firmware version prior to V2.0.0 is prone to improper privilege management. The affected device has a web-based user interface with a role-based access system. Users with different roles have different write and read privileges. The access system is based on dynamic "tokens". The vulnerability is that user sessions are not closed correctly and a user with fewer rights is assigned the higher rights when he logs on. CWE-269Nov 19, 2020 | CVSS9.1v3.1 | EPSS0.908% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |