Showing 16 vulnerabilities on this page for GX Works3

Signals CISA KEV Ransomware Nuclei
Mitsubishi Electric Corporation vulnerability results
VulnerabilityTitle and contextCVSSEPSSPoCsSignalsSTIX action

Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M to 1.626C, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all v

CWE-470Jan 30, 2024
CVSS9.8v3.1EPSS2.13%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M to 1.626C, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticate

CWE-306Jan 30, 2024
CVSS7.5v3.1EPSS0.949%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Malicious Code Execution Vulnerability due to External Control of File Name or Path in multiple Mitsubishi Electric FA Engineering Software Products allows a malicious attacker to execute a malicious code by having legitimate users open a specially crafted project file, which could result in information disclosure, tampering and deletion, or a denial-of-service (DoS) condition.

CWE-610CWE-73Nov 30, 2023
CVSS7.8v3.1EPSS0.261%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Malicious Code Execution Vulnerability in FA Engineering Software Products

Incorrect Default Permissions vulnerability in Mitsubishi Electric Corporation multiple FA engineering software products allows a malicious local attacker to execute a malicious code, resulting in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition, if the product is installed in a folder other than the default installation folder.

CWE-276Sep 20, 2023
CVSS9.3v3.1EPSS0.177%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Insufficiently Protected Credentials vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could access to MELSEC safety CPU modules illgally.

CWE-522Nov 24, 2022
CVSS6.8v3.1EPSS0.985%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Cleartext Storage of Sensitive Information in Memory vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later, GX Works2 all versions and GX Developer versions 8.40S and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could obtain information about the project file for MELSEC safety CPU modules or project file for MELSEC Q/FX/L series with security setting.

CWE-312CWE-316Nov 24, 2022
CVSS3.7v3.1EPSS0.611%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z allows a remote unauthenticated attacker to obtain information about the project file for MELSEC safety CPU modules.

CWE-259CWE-798Nov 24, 2022
CVSS7.5v3.1EPSS1.29%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z, and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.065T allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally.

CWE-321CWE-798Nov 24, 2022
CVSS9.1v3.1EPSS1.21%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, Motion Control Setting(GX Works3 related software) versions from 1.035M to 1.042U, and MT Works2 versions from 1.100E to 1.200J allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.

CWE-321CWE-798Nov 24, 2022
CVSS6.8v3.1EPSS1.03%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project file or execute programs illegally.

CWE-321CWE-798Nov 24, 2022
CVSS6.8v3.1EPSS1.03%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project files or execute programs illegally.

CWE-321CWE-798Nov 24, 2022
CVSS6.8v3.1EPSS1.03%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.087R and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.

CWE-312Nov 24, 2022
CVSS6.8v3.1EPSS0.685%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, and MT Works2 versions from 1.100E to 1.200J allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.

CWE-259CWE-798Nov 24, 2022
CVSS5.6v3.1EPSS0.457%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module.

CWE-312Nov 24, 2022
CVSS8.6v3.1EPSS0.802%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions

CVSS7.5v3.1EPSS6.88%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT Soft

CWE-122CWE-787Feb 19, 2021
CVSS7.5v3.1EPSS3.89%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX