Showing 6 vulnerabilities on this page for BI Connector ODBC Driver

Signals CISA KEV Ransomware Nuclei
MongoDB vulnerability results
VulnerabilityTitle and contextCVSSEPSSPoCsSignalsSTIX action

MongoDB BI Connector ODBC driver may write outside an allocated buffer when the setup dialog opens a data source with oversized path settings

A data source definition containing an over-length file path setting may cause the MongoDB BI Connector ODBC Driver setup dialog to write outside the bounds of an allocated buffer. The issue stems from an incorrect buffer capacity calculation in the dialog's file and folder selection handling, and is reached only when a user opens the setup dialog for such a data source and initiates a file or folder selection. Depending on build configuration, the result may range from abnormal process terminat

CWE-121Aug 12, 2026
CVSS8.4v4.0EPSS0.126%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

MongoDB BI Connector ODBC Driver Memory-Safety Issue When Handling Stored Procedure Output Parameters

An application using the MongoDB BI Connector ODBC Driver may experience a memory-safety issue when processing output parameters from a stored procedure. Triggering this issue requires connecting to an untrusted or impersonated database server that returns crafted metadata. This may result in process termination, disclosure of process memory, or, under certain conditions, arbitrary code execution.

CWE-122Aug 12, 2026
CVSS8.8v4.0EPSS0.364%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

MongoDB BI Connector ODBC driver may write outside an allocated buffer when retrieving large floating point values as character data

The MongoDB BI Connector ODBC Driver converts floating point column values into text without checking that the result fits within the destination buffer. When an application reads a sufficiently large floating point value as text, the driver may write beyond the end of that buffer and corrupt adjacent memory. A user who can store data in a collection read through the BI Connector could use this to crash the application performing the read.

CWE-787Aug 12, 2026
CVSS7.1v4.0EPSS0.289%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

MongoDB BI Connector ODBC driver may write outside an allocated buffer when handling oversized catalog object names

The MongoDB BI Connector ODBC Driver may write outside the bounds of a fixed-size buffer when an application supplies an unusually long catalog, schema, or object name to a metadata retrieval function. This may result in memory corruption within the calling application's process, leading to abnormal termination and, under certain conditions, the potential for arbitrary code execution.

CWE-190Aug 12, 2026
CVSS9.5v4.0EPSS0.377%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

Crafted database metadata may cause memory corruption in MongoDB BI Connector ODBC Driver

A missing bounds check when parsing stored procedure parameter metadata in the MongoDB BI Connector ODBC Driver can result in an out-of-bounds write in the client application process. Triggering this issue requires control over the server the driver connects to, or the ability to respond in its place, in order to return malformed metadata. The resulting memory corruption may cause the client application to terminate abnormally or, under certain conditions, execute unintended code.

CWE-120Aug 12, 2026
CVSS8.8v4.0EPSS0.294%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

MongoDB BI Connector ODBC driver installation via MSI may leave ACLs unset on custom installation directories

Incorrect Default Permissions vulnerability in MongoDB BI Connector ODBC driver allows Privilege Escalation.This issue affects BI Connector ODBC driver: from 1.0.0 through 1.4.6.

CWE-276Oct 23, 2025
CVSS8.8v4.0EPSS0.126%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX