Schneider Electric Vulnerabilities and Affected Products
Vulnerabilities associated with Pro-face BLUE.
Products
Clear product- StruxureWare Data Center Expert15 vulnerabilities
- EcoStruxure Control Expert12 vulnerabilities
- Modicon M340 CPU (part numbers BMXP34*)12 vulnerabilities
- IGSS Data Server (IGSSdataServer.exe)10 vulnerabilities
- PowerChute™ Serial Shutdown10 vulnerabilities
- EcoStruxure Process Expert9 vulnerabilities
- IGSS Dashboard (DashBoard.exe)9 vulnerabilities
- Custom Reports (RMS16.dll)8 vulnerabilities
- IGSS Data Server(IGSSdataServer.exe)8 vulnerabilities
- EcoStruxure™ IT Data Center Expert7 vulnerabilities
- Modicon Controllers M241/M2517 vulnerabilities
- Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)7 vulnerabilities
- Modicon Momentum Unity M1E Processor (171CBU*)7 vulnerabilities
- OPC UA Modicon Communication Module7 vulnerabilities
- Pro-face BLUE7 vulnerabilities
- X80 advanced RTU Communication Module7 vulnerabilities
- Data Center Expert6 vulnerabilities
- EcoStruxure Operator Terminal Expert6 vulnerabilities
- EcoStruxure™ Power Monitoring Expert (PME)6 vulnerabilities
- EcoStruxure™ Power Operation (EPO) Advanced Reporting and Dashboards Module6 vulnerabilities
- Modicon M580 CPU (part numbers BMEP* and BMEH*)6 vulnerabilities
- Sage 14106 vulnerabilities
- Sage 14306 vulnerabilities
- Sage 14506 vulnerabilities
- Sage 24006 vulnerabilities
| Vulnerability | Title and context | CVSS | EPSS | PoCs | Signals | STIX action |
|---|---|---|---|---|---|---|
CVE-2023-1049HIGH | A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause execution of malicious code when an unsuspicious user loads a project file from the local filesystem into the HMI. CWE-94Jun 14, 2023 | CVSS7.8v3.1 | EPSS0.597% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2022-41666HIGH | A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior). CWE-347Nov 4, 2022 | CVSS7.0v3.1 | EPSS0.133% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2022-41667HIGH | A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior). CWE-22Nov 4, 2022 | CVSS7.0v3.1 | EPSS0.215% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2022-41670HIGH | A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior). CWE-22Nov 4, 2022 | CVSS7.0v3.1 | EPSS0.187% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2022-41669HIGH | A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load a malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior). CWE-347Nov 4, 2022 | CVSS7.0v3.1 | EPSS0.11% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2022-41671HIGH | A CWE-89: Improper Neutralization of Special Elements used in SQL Command (‘SQL Injection’) vulnerability exists that allows adversaries with local user privileges to craft a malicious SQL query and execute as part of project migration which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior). CWE-89Nov 4, 2022 | CVSS7.0v3.1 | EPSS0.25% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2022-41668HIGH | A CWE-704: Incorrect Project Conversion vulnerability exists that allows adversaries with local user privileges to load a project file from an adversary-controlled network share which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior). CWE-704Nov 4, 2022 | CVSS7.0v3.1 | EPSS0.197% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |