Tenda Vulnerabilities and Affected Products
Vulnerabilities associated with fh1206_firmware.
Products
Clear product- FH120249 vulnerabilities
- AC744 vulnerabilities
- AC1539 vulnerabilities
- CH2239 vulnerabilities
- fh1206_firmware37 vulnerabilities
- AC1836 vulnerabilities
- AC636 vulnerabilities
- AC10U30 vulnerabilities
- ac930 vulnerabilities
- F45330 vulnerabilities
- AC1029 vulnerabilities
- F45628 vulnerabilities
- AC826 vulnerabilities
- ac525 vulnerabilities
- ax1806_firmware24 vulnerabilities
- fh1201_firmware24 vulnerabilities
- f120223 vulnerabilities
- fh120323 vulnerabilities
- FH45123 vulnerabilities
- ac15_firmware21 vulnerabilities
- WH45021 vulnerabilities
- AC2020 vulnerabilities
- F45120 vulnerabilities
- fh1202_firmware20 vulnerabilities
- AC120619 vulnerabilities
| Vulnerability | Title and context | CVSS | EPSS | PoCs | Signals | STIX action |
|---|---|---|---|---|---|---|
CVE-2024-44386HIGH | Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function fromSetIpBind. CWE-121Aug 23, 2024 | CVSS7.3v3.1 | EPSS0.321% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-44390HIGH | Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function formWrlsafeset. | CVSS8.8v3.1 | EPSS0.296% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-44387MEDIUM | Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the functino formWrlExtraGet. | CVSS6.5v3.1 | EPSS0.265% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-42973HIGH | Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSetlpBind function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | CVSS7.5v3.1 | EPSS0.558% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-42984HIGH | Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromP2pListFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | CVSS7.5v3.1 | EPSS0.557% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-42986HIGH | Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the PPPOEPassword parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | CVSS7.5v3.1 | EPSS0.552% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-42976HIGH | Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSafeClientFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | CVSS7.5v3.1 | EPSS0.557% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-42969HIGH | Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSafeUrlFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | CVSS7.5v3.1 | EPSS0.558% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-42968HIGH | Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the Go parameter in the fromSafeUrlFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | CVSS7.5v3.1 | EPSS0.558% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-42980HIGH | Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ImForm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | CVSS7.5v3.1 | EPSS0.557% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-42979HIGH | Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ProtForm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | CVSS7.5v3.1 | EPSS0.552% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-42981HIGH | Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the delno parameter in the fromPptpUserSetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | CVSS7.5v3.1 | EPSS0.552% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-42983HIGH | Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the pptpPPW parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | CVSS7.5v3.1 | EPSS0.552% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-42982HIGH | Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | CVSS7.5v3.1 | EPSS0.557% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-42985HIGH | Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromNatlimit function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | CVSS7.5v3.1 | EPSS0.552% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-42974HIGH | Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromwebExcptypemanFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | CVSS7.5v3.1 | EPSS0.552% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-42977HIGH | Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the qos parameter in the fromqossetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | CVSS7.5v3.1 | EPSS0.552% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-42987HIGH | Tenda FH1206 v02.03.01.35 was discovered to contain a stack-based buffer overflow vulnerability in the fromPptpUserAdd function. The vulnerability can be triggered via the modino, username, newpwd, or pptpdnetseg parameters, all of which are passed via HTTP POST and used in unsafe sprintf calls without proper length validation. A remote attacker can exploit this flaw through a crafted POST request, which may cause a Denial of Service (DoS). In certain scenarios, this issue could potentially be l… CWE-787Aug 15, 2024 | CVSS7.5v3.1 | EPSS1.31% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-42978CRITICAL | An issue in the handler function in /goform/telnet of Tenda FH1206 v02.03.01.35 allows attackers to execute arbitrary commands via a crafted HTTP request. CWE-78Aug 15, 2024 | CVSS9.8v3.1 | EPSS1.23% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-7707HIGH | Tenda FH1206 HTTP POST Request SafeEmailFilter formSafeEmailFilter stack-based overflowA vulnerability was found in Tenda FH1206 02.03.01.35 and classified as critical. Affected by this issue is the function formSafeEmailFilter of the file /goform/SafeEmailFilter of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | CVSS8.7v4.0 | EPSS1.28% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-7615HIGH | Tenda FH1206 fromSafeUrlFilter stack-based overflowA vulnerability was found in Tenda FH1206 1.2.0.8. It has been declared as critical. Affected by this vulnerability is the function fromSafeClientFilter/fromSafeMacFilter/fromSafeUrlFilter. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | CVSS8.7v4.0 | EPSS1.47% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-7614HIGH | Tenda FH1206 qossetting fromqossetting stack-based overflowA vulnerability was found in Tenda FH1206 1.2.0.8(8155). It has been classified as critical. Affected is the function fromqossetting of the file /goform/qossetting. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | CVSS8.7v4.0 | EPSS1.47% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-7613HIGH | Tenda FH1206 GstDhcpSetSer fromGstDhcpSetSer buffer overflowA vulnerability was found in Tenda FH1206 1.2.0.8(8155) and classified as critical. This issue affects the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | CVSS8.7v4.0 | EPSS1.47% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-35340HIGH | Tenda FH1206 V1.2.0.8(8155) was discovered to contain a command injection vulnerability via the cmdinput parameter at ip/goform/formexeCommand. CWE-77May 24, 2024 | CVSS8.6v3.1 | EPSS1.22% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2024-35339CRITICAL | Tenda FH1206 V1.2.0.8(8155) was discovered to contain a command injection vulnerability via the mac parameter at ip/goform/WriteFacMac. CWE-94May 24, 2024 | CVSS9.8v3.1 | EPSS1.84% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |