Philips Vulnerabilities and Affected Products
Vulnerabilities associated with Brilliance CT Scanners.
Products
Clear product- e-Alert Unit (non-medical device)9 vulnerabilities
- Philips IntelliSpace Portal9 vulnerabilities
- Hue Bridge8 vulnerabilities
- Vue PACS8 vulnerabilities
- Patient Information Center iX (PICiX)7 vulnerabilities
- Vue Motion7 vulnerabilities
- Vue MyVue7 vulnerabilities
- Vue Speech7 vulnerabilities
- Clinical Collaboration Platform5 vulnerabilities
- Brilliance CT Scanners3 vulnerabilities
- IntelliSpace Portal3 vulnerabilities
- MRI 1.5T3 vulnerabilities
- MRI 3T3 vulnerabilities
- Patient Information Center iX (PIC iX)3 vulnerabilities
- PerformanceBridge Focal Point3 vulnerabilities
- SureSigns VS43 vulnerabilities
- DoseWise Portal2 vulnerabilities
- IntelliBridge EC 40 Hub2 vulnerabilities
- IntelliBridge EC 80 Hub2 vulnerabilities
- Intellispace Cardiovascular (ISCV)2 vulnerabilities
- IntelliSpace Cardiovascular (ISCV) products2 vulnerabilities
- IntelliVue MX40 Patient Worn Monitor2 vulnerabilities
- IntelliVue patient monitors2 vulnerabilities
- PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs2 vulnerabilities
- Philips Alice 6 System2 vulnerabilities
| Vulnerability | Title and context | CVSS | EPSS | PoCs | Signals | STIX action |
|---|---|---|---|---|---|---|
CVE-2018-8861HIGH | Vulnerabilities within the Philips Brilliance CT kiosk environment (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) could enable a limited-access kiosk user or an unauthorized attacker to break-out from the containment of the kiosk environment, attain elevated privileges from the underlying Windows OS, and access unauthorized resources from the operating system. CWE-668May 4, 2018 | CVSS8.7v3.0 | EPSS0.411% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2018-8857HIGH | Philips Brilliance CT software (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) contains fixed credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. An attacker could compromise these credentials and gain access to the system. CWE-798May 4, 2018 | CVSS7.8v3.0 | EPSS0.314% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2018-8853HIGH | Philips Brilliance CT devices operate user functions from within a contained kiosk in a Microsoft Windows operating system. Windows boots by default with elevated Windows privileges, enabling a kiosk application, user, or an attacker to potentially attain unauthorized elevated privileges in Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior. Also, attackers may gain access to unauth… | CVSS8.8v3.0 | EPSS0.37% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |