Philips Vulnerabilities and Affected Products
Vulnerabilities associated with Patient Information Center iX (PICiX).
Products
Clear product- e-Alert Unit (non-medical device)9 vulnerabilities
- Philips IntelliSpace Portal9 vulnerabilities
- Hue Bridge8 vulnerabilities
- Vue PACS8 vulnerabilities
- Patient Information Center iX (PICiX)7 vulnerabilities
- Vue Motion7 vulnerabilities
- Vue MyVue7 vulnerabilities
- Vue Speech7 vulnerabilities
- Clinical Collaboration Platform5 vulnerabilities
- Brilliance CT Scanners3 vulnerabilities
- IntelliSpace Portal3 vulnerabilities
- MRI 1.5T3 vulnerabilities
- MRI 3T3 vulnerabilities
- Patient Information Center iX (PIC iX)3 vulnerabilities
- PerformanceBridge Focal Point3 vulnerabilities
- SureSigns VS43 vulnerabilities
- DoseWise Portal2 vulnerabilities
- IntelliBridge EC 40 Hub2 vulnerabilities
- IntelliBridge EC 80 Hub2 vulnerabilities
- Intellispace Cardiovascular (ISCV)2 vulnerabilities
- IntelliSpace Cardiovascular (ISCV) products2 vulnerabilities
- IntelliVue MX40 Patient Worn Monitor2 vulnerabilities
- IntelliVue patient monitors2 vulnerabilities
- PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs2 vulnerabilities
- Philips Alice 6 System2 vulnerabilities
| Vulnerability | Title and context | CVSS | EPSS | PoCs | Signals | STIX action |
|---|---|---|---|---|---|---|
CVE-2020-16212MEDIUM | Philips Patient Monitoring Devices Exposure of Resource to Wrong SphereIn Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vulnerable to local breakouts that could allow an attacker with physical access to escape the restricted environment with limited privileges. CWE-668Sep 11, 2020 | CVSS6.8v3.1 | EPSS0.371% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2020-16220MEDIUM | Philips Patient Monitoring Devices Improper Validation of Syntactic Correctness of InputIn Patient Information Center iX (PICiX) Versions C.02, C.03, PerformanceBridge Focal Point Version A.01, the product receives input that is expected to be well-formed (i.e., to comply with a certain syntax) but it does not validate or incorrectly validates that the input complies with the syntax, causing the certificate enrollment service to crash. It does not impact monitoring but prevents new devices from enrolling. CWE-1286Sep 11, 2020 | CVSS4.3v3.1 | EPSS0.28% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2020-16224MEDIUM | Philips Patient Monitoring Devices Improper Handling of Length Parameter InconsistencyIn Patient Information Center iX (PICiX) Versions C.02, C.03, the software parses a formatted message or structure but does not handle or incorrectly handles a length field that is inconsistent with the actual length of the associated data, causing the application on the surveillance station to restart. CWE-130Sep 11, 2020 | CVSS6.5v3.1 | EPSS0.594% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2020-16228MEDIUM | Philips Patient Monitoring Devices Improper Check for Certificate RevocationIn Patient Information Center iX (PICiX) Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and prior, the software does not check or incorrectly checks the revocation status of a certificate, which may cause it to use a compromised certificate. CWE-299Sep 11, 2020 | CVSS6.4v3.1 | EPSS0.368% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2020-16222HIGH | Philips Patient Monitoring Devices Improper AuthenticationIn Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and PerformanceBridge Focal Point Version A.01, when an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct. CWE-287Sep 11, 2020 | CVSS8.8v3.1 | EPSS0.549% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2020-16214MEDIUM | Philips Patient Monitoring Devices Improper Neutralization of Formula Elements in a CSV FileIn Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software saves user-provided information into a comma-separated value (CSV) file, but it does not neutralize or incorrectly neutralizes special elements that could be interpreted as a command when the file is opened by spreadsheet software. CWE-1236Sep 11, 2020 | CVSS5.0v3.1 | EPSS0.586% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
Philips Patient Monitoring Devices Cross-site ScriptingIn Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access to patient data via a read-only web application. CWE-79Sep 11, 2020 | CVSS3.5v3.1 | EPSS0.653% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |