Schneider Electric SE Vulnerabilities and Affected Products
Vulnerabilities associated with Modicon M221, all references, all versions prior to firmware V1.6.2.0.
Products
Clear product- U.Motion20 vulnerabilities
- Pelco Sarix Professional12 vulnerabilities
- Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR02008 vulnerabilities
- 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS4 vulnerabilities
- Citect Anywhere4 vulnerabilities
- IIoT Monitor 3.1.384 vulnerabilities
- Modicon M221, all references, all versions prior to firmware V1.6.2.04 vulnerabilities
- Modicon M5804 vulnerabilities
- PowerSCADA Anywhere4 vulnerabilities
- U.motion Builder4 vulnerabilities
- Eurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0)3 vulnerabilities
- EVLink Parking v3.2.0-12_v1 and earlier3 vulnerabilities
- Modicon M3403 vulnerabilities
- Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions)3 vulnerabilities
- Modicon Quantum3 vulnerabilities
- Pelco Sarix Professional V13 vulnerabilities
- Pelco VideoXpert Enterprise3 vulnerabilities
- Ampla MES2 vulnerabilities
- BMXNOR0200H Ethernet / Serial RTU module2 vulnerabilities
- ClearSCADA2 vulnerabilities
- Modicon Premium2 vulnerabilities
- Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR02002 vulnerabilities
- SoMachine HVAC Programming Software2 vulnerabilities
- U.motion Server2 vulnerabilities
- Wiser for KNX2 vulnerabilities
| Vulnerability | Title and context | CVSS | EPSS | PoCs | Signals | STIX action |
|---|---|---|---|---|---|---|
CVE-2018-7790CRITICAL | An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a Modicon M221, the attacker can upload the original program from the PLC. CWE-294Aug 29, 2018 | CVSS9.8v3.1 | EPSS2.48% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2018-7791CRITICAL | A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to overwrite the original password with their password. If an attacker exploits this vulnerability and overwrite the password, the attacker can upload the original program from the PLC. | CVSS9.8v3.1 | EPSS1.9% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2018-7792HIGH | A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to decode the password using rainbow table. | CVSS7.5v3.1 | EPSS1.05% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2018-7789HIGH | An Improper Check for Unusual or Exceptional Conditions vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to remotely reboot Modicon M221 using crafted programing protocol frames. CWE-754Aug 29, 2018 | CVSS7.5v3.1 | EPSS2.8% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |